Livraison gratuite + TVA offerte
Livraison gratuite + TVA offerte
Quantity:
The Easun Power Solar Charger Controller allows you to harness the maximum output from your solar system. This controller is exclusively engineered for high performance and efficiency in any solar system.
Get the most out of your solar panel with Maximum Power Point Tracking technology. Advanced MPPT technology ensures the maximum available power from your solar panel, allowing great use of your solar energy.
The automatic detection enabled in the controller works perfectly with most battery systems ranging from 12 V to 24 V, 36 V, and even 48 V. This feature makes the device quite flexible and very reliable in different setups.
Have a three-stage charge that focuses on extending your battery life and enhancing your battery performance. The constant current, constant voltage, and float stages ensure your overall array of batteries is efficiently and safety charged.
Monitoring your system had never been so easy with the multi-function LCD display. This intuitive user interface gives you real-time performance data, as well as system status, enabling you to carry out full management of your solar power system.
Have a safe, long-lasting solar investment with the Protections. It comes with reverse polarity and overcharge protection, which guard against possible damages for continuous operation.
you can Put two pieces 60A in parallel ,So total is MPPT 120A
Support unlimited parallel connection
|
Item |
Parameter |
||||||
|
Models |
IChargerMPPT6048 |
||||||
|
Chargingmode |
3-stage:constantcurrent(MPPT),constantvoltage,floating |
||||||
|
SystemVoltage |
12/24/36/48/Auto |
||||||
|
MaxPVInputPower |
720W/12V; 1440W/24V2160W/36V; 2880W/48V |
||||||
|
MaxPVInput Voltage |
190Voc |
||||||
|
Batteryvoltageautomaticrecognition |
12Vsystem(DC8.7V-DC15.5V);24Vsystem(DC16V-DC31V) 36Vsystem(DC33V-DC41V);48Vsystem(DC42V-DC64V) |
||||||
|
Overchargingprotectionvoltage |
12V system (16V);24V system (32V)36Vsystem(48V);48Vsystem(64V) |
||||||
|
Limitedcurrentprotection |
61A |
||||||
|
Maxefficiency |
≥98.1% |
||||||
|
PVutilization |
≥99% |
||||||
|
AutoTemperatureCompensation |
-3mV/2V/ºC |
||||||
|
ProtectionFunction |
|||||||
|
Temperatureprotection |
75℃ |
||||||
|
Fan-ontemperature |
>45℃ |
||||||
|
Fan-offtemperature |
<40℃ |
||||||
|
Properties |
|||||||
|
Size(mm) |
214x115x50 |
||||||
|
Netweight(Kg) |
1.1 |
||||||
|
Grossweight(Kg) |
1.2 |
||||||
|
Electromagneticcompatibility |
AccordtoEN61000,EN55022,EN55024 |
||||||
|
Enclosure |
IP21 |
||||||
|
Environmentaltemperature |
-20℃~+55℃ |
||||||
|
Storagetemperature |
-40℃~+75℃ |
||||||
|
BatteryParameters |
|||||||
|
BatteryType |
SystemVolt |
EQU |
BST |
FLD |
BST_R |
LRV |
LDV |
|
GEL |
Auto |
14.2V |
14.2V |
13.8V |
13.2V |
12.6V |
12.0V |
|
SEL |
Auto |
14.6V |
14.4V |
13.8V |
13.2V |
12.6V |
12.0V |
|
FLD |
Auto |
14.8V |
14.6V |
13.8V |
13.2V |
12.6V |
12.0V |
|
USE |
Auto/12/24/36/48V |
Definedbyusers |
|
|
|
|
|
|
LI |
12/24/36/48V |
--- |
Definedbyusers |
--- |
--- |
Definedbyusers |
|
|
ThemaximumPVinputpower(ThetotalpowerratedofPVcan’tbeoverthiswattthatwillbreakthe controller.) |
12Vsystem(360W) |
12Vsystem(480W) |
12Vsystem(600W) |
12Vsystem(720W) |
|||
|
24Vsystem(720W) |
24Vsystem(960W) |
24Vsystem(1200W) |
24Vsystem(1440W) |
||||
|
36Vsystem(1080W) |
36Vsystem(1400W) |
36Vsystem(1800W) |
36Vsystem(2100W) |
||||
|
48Vsystem(1440W) |
48Vsystem(1700W) |
48Vsystem(2200W) |
48Vsystem(2800W) |
||||










FAQ short paragraph
Un onduleur hors réseau permet d’alimenter vos appareils à partir des panneaux solaires et des batteries, sans injecter d’électricité dans le réseau public.
Les panneaux solaires peuvent alimenter les charges tout en rechargeant la batterie. Lorsque l’énergie solaire ou la batterie devient insuffisante, le système bascule automatiquement en mode bypass pour utiliser le réseau électrique.
Un onduleur hybride combine les fonctions d’un onduleur hors réseau avec la possibilité d’injecter l’énergie excédentaire dans le réseau électrique.
Les panneaux solaires et les batteries peuvent alimenter les appareils domestiques, tandis que le réseau électrique peut également intervenir si nécessaire.
Nos onduleurs sont compatibles avec :
Les batteries LiFePO4 et les batteries de type Pylontech sont compatibles avec nos onduleurs.
Les batteries peuvent être connectées en série ou en parallèle selon la configuration.
Les onduleurs prennent en charge :
Le nombre de panneaux dépend de :
La tension totale des panneaux ne doit jamais dépasser la tension maximale d’entrée de l’onduleur.
Tous les modèles hybrides peuvent fonctionner sans batterie.
Oui. Certains modèles prennent en charge le fonctionnement en parallèle.
Veuillez nous contacter avant l’achat afin de recevoir la solution adaptée.
Oui. La sortie de l’éolienne doit être connectée à la batterie, et non directement à l’onduleur.
Oui. Les générateurs essence ou diesel peuvent être connectés à l’entrée AC de l’onduleur.
La puissance du générateur doit être au moins deux fois supérieure à celle de l’onduleur.
Les panneaux doivent être connectés en respectant :
Pour les séries II et III, la tension PV recommandée doit être supérieure à 200V en connexion série.
Intensité lumineuse et angle d’installation
Ombres partielles ou complètes
Effet de point chaud causé par des dommages au panneau
La consommation à vide est d’environ 1A.
Par exemple, un onduleur 24V consomme environ 24W sans charge.